Showing posts with label Power system protection. Show all posts
Showing posts with label Power system protection. Show all posts

Power System Protection MCQs - Quiz 2 (Circuit Breakers)

Wednesday, March 14, 2018

CIRCUIT BREAKERS

1. In air circuit breakers ___ is used to suppress the arc.
A) Water
B) Air
C) Oil
D) Nitrogen


2. In oil circuit breakers the function of oil is:
A) Cooling
B) Insulation
C) Rust protection
D) Arc suppression


3. The contacts in circuit breakers are made of:
A) Carbon
B) Copper alloy
C) Tungsten
D) Cast iron


4. Which of the following is a routine test in circuit breakers?
A) Contact resistance test
B) Insulation resistance test
C) Timing tests
D) All of above


5. ___ is the voltage that appears across the contacts of the circuit breaker after arc extinction.
A) Surge
B) Recovery
C) Nominal
D) Operating


6. SF6 gas is:
A) Colorless
B) Odorless
C) Not inlfamable
D) All of above


7. The power for shunt trip circuit breaker comes from:
A) Within the breaker
B) External source
C) Either of A or B


8. According to IEC high voltage (HV) circuit breakers are used for ___ voltages.
A) 1 kV or higher
B) 33 kV or higher
C) 72.5 kV or higher
D) None of above


9. Circuit breaker are actuated through ___ mechanism.
A) Hydraulic
B) Pneumatic
C) Spring
D) All of above


10. The trip action in a magnetic circuit breaker is:
A) Instantaneous
B) Delayed
C) Both A & B


Read more...

Power System Protection MCQs - Quiz 1

Monday, March 5, 2018

1. Insulation resistance of HV circuit breakers is more than ___ mega ohms.
A) 1
B) 10
C) 100
D) 1000


2. Which of the following is the least expensive overcurrent protection for LV system?
A) Isolator
B) Rewireable fuse
C) Oil circuit breaker
D) None of the above


3. The contacts of high voltage breakers used in power system are submerged in oil to:
A) Extinguish the arc
B) Insulate the contacts from switch body
C) Lubricate the contacts
D) None of the above


4. To protect most of the electrical equipment handling low power, the types of relays used are:
A) Thermocouple
B) Electronic and bimetallic
C) Both A & B
D) None of the above


5. The co-efficient of reflection at the open circuited end of a transmission line is:
A) Zero
B) Unity
C) Infinity
D) None of the above


6. A ___ is used to measure the stator winding temperature in a generator.
A) Resistance thermometer
B) Pyrometer
C) Thermocouple
D) Thermometer


7. The under voltage relay can be used for:
A) Generators
B) Busbars
C) Transformers
D) All of the above


8. Which of these devices will receive voltage surge first travelling on the transmission line?
A) Relays
B) Lightning arresters
C) Step down transformer
D) Switchgear


9. Which of the following parameters can be neglected for a short line?
A) Resistance
B) Capacitance
C) Inductance
D) Reactance


10. The relay with inverse time characteristic will operate within ___ sec.
A) 20 to 30
B) 5 to 20
C) 5 to 10
D) None of the above

Read more...